This page is a work in progress. Please be sure to read and be familiar with the Emulab documentation.
The testbed needs to know what switches are connected to it and what power ports they are plugged into. Right now, we insert these manually into the database.
Testbed nodes need to be setup to boot from the network by default. This is done through the Preboot eXecution Environment, available for most network cards. For onboard network cards, it is typically enabled through the BIOS.
In order to add our switch to the database, we need to setup node and interface types for them.
We provide some SQL to make this easy. The script switch-types-create defines the following:
For other switch types, please refer to the Emulab Documentation.
To load these default node and interface types, simply:
mysql tbdb < ~<builduser>/testbed/sql/interface-types-create.sql mysql tbdb < ~<builduser>/testbed/sql/switch-types-create.sql
Your switch needs a name that resolves. You must add it either to /etc/hosts or to the name server running on boss.
To add it to the name server, add it into /etc/namedb/<yoursitename>.internal.db.head. You then refresh the DNS server by running /usr/testbed/sbin/named_setup.
For example, on mini-isi.deterlab.net we have our switch that we will name hp1 at 192.168.254.1 on the HARDWARE_CONTROL network. So we add it to DNS as follows:
[jhickey@boss ~]$ sudo su - boss# echo "hp1 IN A 192.168.254.1" >> /etc/namedb/mini-isi.deterlab.net.internal.db.head boss# logout [jhickey@boss ~]$ /usr/testbed/sbin/named_setup [jhickey@boss ~]$ ping -c 1 hp1 PING hp1.mini-isi.deterlab.net (192.168.254.1): 56 data bytes 64 bytes from 192.168.254.1: icmp_seq=0 ttl=63 time=3.496 ms --- hp1.mini-isi.deterlab.net ping statistics --- 1 packets transmitted, 1 packets received, 0.0% packet loss round-trip min/avg/max/stddev = 3.496/3.496/3.496/0.000 ms [jhickey@boss ~]$
Using the hostname you have given your switch, insert a line in the the nodes table in the database. If you are adding a dedicated control network switch, use ctrlswitch as the role. Otherwise, the role is testswitch.
insert into nodes set node_id='hp1',phys_nodeid='hp1',type='hp2180',role='testswitch';
If your installation has more than one switch, we need to tell the database about it so that vlan trunking can be enabled and so that it doesn't try to oversubscribe the link. We created interface types earlier in this document. Let's say we have hp1 and hp2 which are connected by a single 1GbE link. hp2 module A, port 5 is connected to hp1 module B, port 23. We need to add two lines to the interfaces table (note that current_speed is in Mbits now):
insert into interfaces set node_id='hp1',card=2,port=23,mac='000000000000',iface='B/23',role='other', current_speed='1000',interface_type='trunk_1GbE',uuid=UUID(); insert into interfaces set node_id='hp2',card=1,port=5,mac='000000000000',iface='A/5',role='other', current_speed='1000',interface_type='trunk_1GbE',uuid=UUID();
We also need to add an entry to the wires table for these two switches:
insert into wires set node_id1='hp1',card1=2,port1=23, node_id2='hp2',card2=1,port2=5, type='Trunk';
Note: For switches that are not modular, set card to 0, not 1.
The idea of switch stacks comes from sites that run separate control and experimental networks. In this scenario, it does not make sense to create experimental vlans on switches that function only as control network switches and vice versa. The typical DETER deployment scenario will be a switch that handles both. In this case, we add the same switch to the two different stacks ('Experiment' and 'Control' which we also have to setup in switch_stack_types). We also make sure that is_primary is set to 1 for the Experimental stack line and 0 for the Control stack line (I assume so that we only try creating vlans once per switch).
First, create our switch_stack_types. For our mini-isi setup, we have the two types:
insert into switch_stack_types (stack_id, stack_type, snmp_community, leader) values ('Control', 'generic', 'private', 'hp1'); insert into switch_stack_types (stack_id, stack_type, snmp_community, leader) values ('Experiment', 'generic', 'private', 'hp1');
So in our mini-isi example, we need to add in two entries for our switch hp1:
insert into switch_stacks (node_id,stack_id,is_primary) values ('hp1','Experiment',1), ('hp1','Control',0);
On boss, run wap snmpit -l -l to list all vlans. For example, your output should look something like this (right now there might be some MIB warnings):
[jhickey@boss ~]$ wap snmpit -l -l VLAN Project/Experiment VName Members -------------------------------------------------------------------------------- CONTROLH CONTROLHW hp1.1/3 hp1.1/4 hp1.1/5 CONTROL CONTROL hp1.1/3 hp1.1/6 hp1.1/7 hp1.1/8 hp1.1/9 hp1.1/10 hp1.1/11 hp1.1/12 INTERNET INTERNET hp1.1/1 hp1.1/2 hp1.1/3 BOSS BOSS hp1.1/3 [jhickey@boss ~]$
Add in a node_type for your power controller. We assume you are using an APC 7902 networked power controller:
insert into `node_types` (class, type) values ('power','APC');
Now add in a node entry for the power controller:
insert into nodes set node_id='apc23',phys_nodeid='apc23',type='APC',role='powerctrl';
TBD
When the PXE boot ROM is loaded during machine boot.
The default bootloader for testbed nodes is /tftpboot/pxeboot.emu. There are four different versions of pxeboot.emu distributed with the tarball.
Pick a loader that best suits your installation and copy it:
cp /tftpboot/pxeboot.emu-<null|sio|sio2|vga> /tftpboot/pxeboot.emu
You can also look at modifying /usr/local/etc/dhcpd.conf.template. You will have to generate a new dhcpd.conf configuration using /usr/testbed/sbin/dhcpd_makeconf > /usr/local/etc/dhcpd.conf and restarting dhcpd.
These filesystems are PXE booted over the network via TFTP and allow us to perform various parts of node maintenance.
There are three different MFS (memory file system) images that come with DETER/Emulab.
They are:
The reason all these tasks are split up among multiple images is to keep the image size down since they are booted over the network. With faster networks, these images will likely be rolled into a single Linux based image in the future.
You will have to install your root SSH keys from boss into each MFS and change the root password.
This process has been automated by the script setup_mfs in testbed/install.
Generally each node will have a control network interface and experimental interfaces. The control network interface should be on a switch port that is on the CONTROL (VLAN 2003) network. The experimental interfaces should be on ports that are enabled, but can be in a default VLAN for now.
The testbed nodes should be set to boot only off of the network. Disable hard drive boot to prevent failed PXE requests from falling through to booting whatever is on the disk.